FACP IQ8Control M (808004)
View Details
Buy Now
Rated voltage 230 V AC
Rated current 0,35 A (standard); 0.7 A (powered loop)
Output voltage 12 V DC
Quiescent current approx. 215 mA (basic configuration without operating unit) approx. 230 mA (basic configuration with operating unit)
Current consumption for ext. devices 2 A 6. Battery capacity max. 2 x 12 V/24 Ah
Ambient temperature -5 °C ... 45 °C
Storage temperature -10 °C ... 50 °C
Air humidity < 95 %
Type of protection IP 30
Housing ABS, 10 % glass fiber reinforced, V - 0
Color gray, similar to Pantone 538
Dimensions W: 450 mm H: 640 mm D: 185 mm
Declaration of Performance DoP-20827130701
FACP IQ8 Control C (808003)
View Details
Buy Now
Rated voltage 230 V AC
Rated frequency 50 Hz ... 60 Hz
Rated current 0,35 A (standard); 0.7 A (powered loop)
Output voltage 12 V DC
Quiescent current approx. 215 mA (basic configuration without operating unit) approx. 230 mA (basic configuration with operating unit)
Current consumption for ext. devices 2 A 7. Battery capacity 2 x 12 Ah, 2 x 24 Ah in extension housing
Ambient temperature -5 °C ... 45 °C
Storage temperature -5 °C ... 50 °C
Air humidity < 95 %
Type of protection IP30
Housing ABS, 10 % glass fiber reinforced, V - 0
Color gray similar to Pantone 538
Weight approx. 6,5 kg
Dimensions W: 450 mm H: 320 mm D: 185 mm
Declaration of Performance DoP-20827130701
RS 232/TTY serial interface module (784842)
View Details
Buy Now
Quiescent current
approx. 35 mA (RS 232)
approx. 55 mA (TTY)
Loop module esserbus-PLus (Powered Loop) (804382.D0)
View Details
Buy Now
Quiescent current
approx. 60 mA
Peripheral module with 1 additional micromodule slot (772477)
View Details
Buy Now
Quiescent current
approx. 15 mA (without micromodule)
Extension module with 3 additional micromodule slots (772476)
View Details
Buy Now
Quiescent current
approx. 5 mA (without micromodule)
essernet module, 500 kBd for IQ8Control (784841.1)
View Details
Buy Now
Quiescent current @ 12 V DC approx. 150 mA
Cable length 1000 m
Cable IBM Typ1, Typ1A, Typ2, Typ2A, Typ6, CAT 5, CAT6, CAT7 or similar
Rate-of-rise heat detector IQ8Quad with isolator (802271)
View Details
Buy Now
Operating voltage 8 ... 42 V DC
Quiescent current @ 19 V DC 40 μA
Quiescent current @ FACP battery approx. 220 μA
Alarm current w/o communication curtain 18 mA
Area to be monitored 30 m²
Height to be monitored 7,5 m
Air velocity 0 m/s ... 25,4 m/s
Application temperature -20 °C ... 50 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 40 with base, up to IP 43 with base and option
Material ABS plastic
Color white, similar to RAL 9010
Weight approx. 110 g
Detector specification EN 54-5 A1R / -17:2005
Dimensions Ø: 117 mm H: 49 mm (62 mm incl. base)
Declaration of Performance DoP-20103130701
O/So Optical Smoke Detector + Sounder IQ8Quad (802382)
View Details
Buy Now
Detection
The reliable sensor principle for consistent response performance at the highest level of security against false alarms
Sounder
Loop powered - no need for external power supply
Individual control of the sounder
Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools (school bell) etc.
Soft start option, ideal for hospitals and nursing homes
No additional short address
Automatic synchronization of various IQ8Quad alarm signaling devices
Maximum sound level: 92 dB (A) at 1 m
Maximum sound pressure can be set
Multiple signal components can be combined to one signal template
Signal template and repetition rates can be set
Up to 26 different languages are available
20 different signal tones, incl. DIN-tone
Low power consumption
OT multisensor fire detector IQ8Quad with isolator (802373)
View Details
Buy Now
Operating voltage 9 ... 42 V DC
Quiescent current @ 19 V DC 50 μA
Quiescent current @ FACP battery approx. 280 μA
Alarm current w/o communication curtain 18 mA
Area to be monitored 110 m²
Height to be monitored 12 m
Air velocity 0 m/s ... 25,4 m/s
Application temperature -20 °C ... 50 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 40 with base, up to IP 43 with base and option Material ABS plastic Color white, similar to RAL 9010 Weight approx. 110 g
Detector specification EN 54-7 /-5 A2 /-17:2005, CEA 4021 Dimensions Ø: 117 mm H: 49 mm (62 mm incl. base)
Declaration of Performance DoP-20111130701
O2T/Sp multisensor fire detector IQ8Quad with isolator (802386)
View Details
Buy Now
Operating voltage 8 ... 42 V DC
Quiescent current @ 19 V DC 90 μA
DQuiescent current @ FACP battery approx. 500 μAemo
Load factor 3 Area to be monitored 110m²
Height to be monitored 12 m
Air velocity 0m/s ... 25,4 m/s
Application temperature -20 °C ... 65 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP43 (with base + options) Material ABS plastic
Color white, similar to RAL 9010 Weight approx. 145 g
Detector specification EN 54-7:2006/-5 B:2000/ -17:2005, CEA 4021
Specification EN 54-3 acoustic signaling device EN 54-3 acoustic speech signaling device
DDimensions Ø: 117 mm H: 59 mm Ø: 117 mm H: 67 mm (incl. base)emo
Declaration of Performance DoP-20192130701
Optical smoke detector IQ8Quad without isolator (803371)
View Details
Buy Now
Operating voltage 8 ... 42 V DC
Quiescent current @ 19 V DC 50 μA
Alarm current w/o communication curtain 18 mA
Area to be monitored 110 m²
Height to be monitored 12 m
Air velocity 0 m/s ... 25,4 m/s
Application temperature -20 °C ... 72 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 40 with base, up to IP 43 with base and option
Material ABS plasti
Color white, similar to RAL 9010
Weight approx. 110 g
Detector specification EN 54-7
Dimensions Ø: 117 mm H: 49 mm (62 mm incl. base)
Declaration of Performance DoP-20931130701
O2T multisensor fire detector IQ8Quad without isolator (803374)
View Details
Buy Now
Operating voltage 8 ... 42 V DC
Quiescent current @ 19 V DC 60 μA
Alarm current w/o communication curtain 18 mA
Area to be monitored 110 m²
Height to be monitored 12 m
Air velocity 0 m/s ... 25,4 m/s
Application temperature -20 °C ... 65 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 40 with base, up to IP 43 with base and option
Material ABS plastic
Color white, similar to RAL 9010
Weight approx. 110 g
Detector specification EN 54-7/-5 B, CEA 4021
Dimensions Ø: 117 mm H: 49 mm (62 mm incl. base)
Declaration of Performance DoP-20319130701
O2T multisensor fire detector IQ8Quad with isolator (802374)
View Details
Buy Now
Operating voltage 8 ... 42 V DC
Quiescent current @ 19 V DC 60 μA
Alarm current w/o communication curtain 18 mA
Area to be monitored 110 m²
Height to be monitored 12 m
Air velocity 0 m/s ... 25,4 m/s
Application temperature -20 °C ... 65 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 40 with base, up to IP 43 with base and option
Material ABS plastic
Color white, similar to RAL 9010
Weight approx. 110 g
Detector specification EN 54-7 /-5 B /-17:2005, CEA 4021
Dimensions Ø: 117 mm H: 49 mm (62 mm incl. base)
Declaration of Performance DoP-20105130701
Rate-of-rise heat detector IQ8Quad with isolator (802271)
View Details
Buy Now
Operating voltage 8 ... 42 V DC
Quiescent current @ 19 V DC 40 μA
Quiescent current @ FACP battery approx. 220 μA
Alarm current w/o communication curtain 18 mA
Area to be monitored 30 m²
Height to be monitored 7,5 m
Air velocity 0 m/s ... 25,4 m/s
Application temperature -20 °C ... 50 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 40 with base, up to IP 43 with base and option
Material ABS plastic
Color white, similar to RAL 9010
Weight approx. 110 g
Detector specification EN 54-5 A1R / -17:2005
Dimensions Ø: 117 mm H: 49 mm (62 mm incl. base)
Declaration of Performance DoP-20103130701
Rate-of-rise heat detector IQ8Quad without isolator (803271)
View Details
Buy Now
Operating voltage 8 ... 42 V DC
Quiescent current @ 19 V DC 40 μA
Alarm current w/o communication curtain 18 mA
Area to be monitored 30 m²
Height to be monitored 7,5 m
Air velocity 0 m/s ... 25,4 m/s
Application temperature -20 °C ... 50 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 40 with base, up to IP 43 with base and option
Material ABS plastic
Color white, similar to RAL 9010
Weight approx. 110 g
Detector specification EN 54-5 A1R
Dimensions Ø: 117 mm H: 49 mm (62 mm incl. base)
Declaration of Performance DoP-DoP-20930130701
O2T/So multisensor fire detector IQ8Quad with isolator (802384)
View Details
Buy Now
Operating voltage 8 ... 42 V DC
Quiescent current @ 19 V DC 80 μA
Quiescent current @ FACP battery approx. 450 μA
Load factor 2
Area to be monitored 110 m²
Height to be monitored 12 m
Air velocity 0 m/s ... 25,4 m/s
Application temperature -20 °C ... 65 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 40 with base, up to IP 43 with accessory
Material ABS plastic
Color white, similar to RAL 9010
Weight approx. 145 g
Detector specification EN 54-7:2006/-5 B:2000/ -17:2005, CEA 4021
Specification EN 54-3 acoustic signaling device
Dimensions Ø: 117 mm H: 59 mm Ø: 117 mm H: 67 mm (incl. base)
Declaration of Performance DoP-20192130701
O2T/F multisensor fire detector IQ8Quad with isolator (802383)
View Details
Buy Now
perating voltage 8 ... 42 V DC
Quiescent current @ 19 V DC 75 μA
Quiescent current @ FACP battery approx. 400 μA
Alarm current 10 mA ... 20 mA
Load factor 2
Lighting energy approx. 3 Y
Luminous intensity max. 15.8 cd peak / 2.63 cd effective
Signal flashing lamp red
Area to be monitored 110 m²
Height to be monitored 12 m
Air velocity 0 m/s ... 25,4 m/s
Application temperature -20 °C ... 65 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP43 (with base + options)
Material ABS plastic
Color white, similar to RAL 9010
Weight approx. 145 g
Detector specification EN 54-7:2006/-5 B:2000/ -17:2005, CEA 4021
Dimensions Ø: 117 mm H: 59 mm Ø: 117 mm H: 67 mm (incl. base)
Declaration of Performance DoP-20193130701
Optical smoke detector IQ8Quad with isolator (802371)
View Details
Buy Now
Operating voltage 8 ... 42 V DC
Quiescent current @ 19 V DC 50 μA
Quiescent current @ FACP battery approx. 280 μA
Alarm current w/o communication curtain 18 mA
Area to be monitored 110 m²
Height to be monitored 12 m
Air velocity 0 m/s ... 25,4 m/s
Application temperature -20 °C ... 72 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 40 with base, up to IP 43 with base and option
Material ABS plastic
Color white, similar to RAL 9010
Weight approx. 110 g
Detector specification EN 54-7 /-17:2005
Dimensions Ø: 117 mm H: 49 mm (62 mm incl. base)
Declaration of Performance DoP-20104130701
IQ8MCP compact, small, red, with isolator and glass pane (804971)
View Details
Buy Now
Operating voltage 8 ... 42 V DC
Quiescent current @ 19 V DC 45 μA
Alarm current w/o communication curtain 18 mA
No. of detector/zone max. 127 detectors per loop (according to VdS)
Operation indicator LED, green
Alarm display red LED and yellow actuation indicator
Connection terminal max. 2.5 mm² (AWG 26-14)
Application temperature -20 °C ... 70 °C
Storage temperature -30 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 43, IP 55 with cover 704965
Housing PC ASA plastic
Color red, similar to RAL 3020
Weight approx. 110 g
Detector specification EN 54-11, type A
Dimensions W: 88mm H:88mm D:21mm W:88 mm H: 88 mm D: 57 mm (with surface mount housing)
Declaration of Performance DoP-20492130701
Small conventional MCP Ex (i) IP 66/67, red with glass pane (804960.EX)
View Details
Buy Now
Operating voltage 8 ... 30 V DC
Alarm current @ 9 V DC 9 mA
Alarm display red LED and yellow actuation indicator
Connection terminal max. 1,5 mm² (AWG 30-14)
Application temperature -20 °C ... 70 °C
Storage temperature -30 °C ... 75 °C
Ex. protection Ex ib II C T4 Gb
Category II2G (with Ex barrier Part No. 764744/804744)
Housing PC ASA plastic
Color red, similar to RAL 3020
Weight approx. 255 g
Dimensions W: 88 mm H: 88 mm D: 63 mm (with surface mount housing)
Declaration of Performance DoP-21415141219
Large Conventional MCP Ex (i), red with glass pane (804920.EX)
View Details
Buy Now
Operating voltage 8 ... 30 V DC
Quiescent current @ 9 V DC 0 μA Alarm current @ 9 V DC 9 mA
Alarm display LED, red Connection terminal max. 1,5 mm² (AWG 30-14)
Application temperature -20 °C ... 70 °C
Storage temperature -30 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 44, IP 55 with shrink sleeve
Ex. protection Ex ib II C T4 Gb
Category II2G (with Ex barrier Part No. 764744/804744)
Housing PC ASA plastic
Color red, similar to RAL 3020
Weight approx. 236 g (in housing)
Dimensions W: 133 mm H: 133 mm D: 36 mm
Declaration of Performance DoP-21417141219
Explosion-proof conventional MCP, IP66 (761697)
View Details
Buy Now
Operating voltage 12 ... 24 V DC
Alarm current approx. 9 mA
No. of detector/zone max. 10 detectors per Zone (according to VdS)
Circuit 1 k/10 k (internal)
Connection terminal 0.6 mm ... 4 mm²
Application temperature -55 °C ... 65 °C
Storage temperature -55 °C ... 85 °C
Air humidity < 95 %
Protection class IP 66
Ex. protection Ex de mb II C T6 Gb, T5 Gb / Ex tb IIIC T100° Db IP66
Category II2G
Housing Glass fiber reinforced polyester resin / Menzolit BMC 2600 (chemical stable, all metal parts made of stainless steel)
Color red, similar to RAL 3000
Weight approx. 1,8 kg
Detector specification DIN14678 Form K
Dimensions W:136mm H:138mm D:88mm
IQ8Alarm Plus/So sounder, red (807205R)
View Details
Buy Now
Load factor acoustic 1,5 *1 / 3
Sound level 91 *1 / 97 dB (A) +/- 2 dB @ 1 m / @ 90° angle / @ DIN Tone
Specification EN 54-3: 2001 / A1: 2002 / A2 : 2006 / -17: 2005 EN 54-3 Sounder
Operating voltage 14 ... 42 V DC (via powered loop)
Quiescent current @ 19 V DC 55 μA
Quiescent current @ FACP battery approx. 300 μA @ 42 V
Connection terminal max. 1,5 mm² (AWG 30-14)
Ambient temperature -10 °C ... 55 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 % (non-condensing)
Type of protection IP 43 *2 IP 56 with IP base 806202 *3
Housing Polycarbonate plastic
Color red, similar to RAL 3020
Weight approx. 300 g (with base)
Dimensions Ø: 112 mm D: 78 mm Ø: 112 mm D: 93 mm (with IP base)
Declaration of Performance DoP-21430171215
IQ8Alarm Plus/F visual alarm device, red/red (807224RR)
View Details
Buy Now
Load factor optic 3 *1 ... 7,9
Frequency of flash 0,5 Hz *1 /1 Hz
Flash color red
Luminous intensity approx. 6,6 cd eff. *1 / max. 17 cd eff. @ W-3,6-8
Signal Range W-2,4-5 / 60 m³ *1 … W-3,6-8 / 230 m³
Mounting Wall
Specification EN 54-23: 2010 / -17: 2005 Acoustic
Operating voltage 14 ... 42 V DC (via powered loop)
Quiescent current @ 19 V DC 55 μA
Quiescent current @ FACP battery approx. 300 μA @ 42 V
Connection terminal max. 1,5 mm² (AWG 30-14)
Ambient temperature -20 °C ... 70 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 % (non-condensing)
Type of protection IP 43 *2 IP 56 with IP base 806202 *3
Housing Polycarbonate plastic
Color red, similar to RAL 3020 Calotte: translucent / partially frosted
Weight approx. 300 g (with base)
Dimensions Ø: 112 mm H: 78 mm Ø: 112 mm H: 93 mm (with IP base)
Declaration of Performance DoP-21429150413
Remote indicator for Series 9000, 9200 and IQ8Quad, red lens (781814 / 801824)
View Details
Buy Now
Operating voltage 1,8 ... 3 V DC
Current consumption approx. 9 mA
Alarm display 3 red LEDs
Ambient temperature -25 °C ... 70 °C
Storage temperature -35 °C ... 85 °C
Air humidity < 95 %
Type of protection IP 42 Housing ABS plastic
Color white, similar to RAL 9010
Weight approx. 60 g
Dimensions W: 85mm H: 82mm D: 27mm
Esserbus alarm transponder, 4 IN/2 OUT with isolator (808623)
View Details
Buy Now
Operating voltage 10 ... 28 V DC
Quiescent current@12V DC approx. 12 mA
Current consumption max. 120 mA @ 12 V DC
Contact load relay 30 V DC / 1 A
Ambient temperature -10 °C ... 50 °C
Storage temperature -25 °C ... 75 °C
Air humidity < 95 %
Type of protection IP 40 (in housing)
Weight approx. 28 g
Dimensions W: 82mm H: 72mm D: 20mm
Declaration of Performance DoP-21057130701
DXC1,DXC2,DX4 (DXC SERIES)
View Details
Buy Now
Loop Capacity ( 99 Detectors +99 Devices)
Networking up to 16 loops (Combination of 1; 2 & 4 Loops)
6x40 characters, blue liquid crystal display with backlight illumination
Configuration by keypad and PC
160 Fire Zones
Fire, Fault, and Auxiliary relays
Loop-Battery calculator for reliable system design
7-day timer
Onboard diagnostic
EN54-2, EN54- 4, LPCB approved
Optional: 40, 80 or 160 zone alarm LEDs
ZX1Se, ZX2Se,ZX5Se (ZXSe Series)
View Details
Buy Now
Scalable platform which can support up to 99 on a single network
Simple integration with VA/PA and other systems
Seamless support of industry-leading detection device protocols
Easy to follow menu supports all standard maintenance activities
Wide range of supporting equipment, such as printers, mounting accessories and repeaters provides maximum system flexibility
Simple programming with the off-line system configuration tool
Designed to comply with EN54 Parts 2 & 4
ACTIVE REPEATER PANEL (709-601-001)
View Details
Buy Now
Compatible with all Morley-IAS intelligent multiprotocol fire alarm control panels
Connects to RS485 peripheral bus
Active or Passive options
Backlit adjustable alphanumeric display
General status LEDs
Controls for system reset, accept, mute, silence alarms, and self test (active repeater only)
“Access Enable” key-switch on active repeater
SMOKE DETECTOR (HM-PSE-S2-IV)
View Details
Buy Now
Weight: 97g (base inc)
Dimensions (Ø x h): 102 mm x 43 mm in base B501AP
Approved to: EN54-7, EN54-5
HEAT DETECTOR (HM-RHSE-S2-IV)
View Details
Buy Now
Weight: 88g (without base)
Dimensions (Ø x h): 102 mm x 61 mm in base B501AP
Approved to: EN54-5. Class A1S
MULTISENSOR (HM-PTSE-S2-IV)
View Details
Buy Now
Weight: 97g (base inc)
Dimensions (Ø x h): 102 mm x 43 mm in base B501AP
Approved to: EN54-7, EN54-5
SOUNDER BASE (BSO-DD-N05)
View Details
Buy Now
Automatic synchronisation of sounder
Low current draw enables more devices on loop
Adjustable volume control (on device or from panel)
Intense strobe output
Deep and high IP base options
Pure White or Ivory body colours
High quality robust materials for longer life
Robust construction for added impact resistance
Addressable Beam Detector (HM-LPB2-S2 I)
View Details
Buy Now
Addressable loop powered beam detector
Rotary decade address switches
10-100m range (from 70 to 100 m requires 6500-LRK)
4 fixed sensitivity levels
2 automatic variable sensitivity modes
Numerical indicators to aid beam alignment
Standby, Fault and Alarm LED indicator
Specifications: EN54-12, EN54-17
BRE approved
Manual call point (HM-MCP-GLASS-AP)
View Details
Buy Now
Unique ‘Plug & Play’ installation concept
Re-settable operating element option
Analogue addressable communications
Fully compliant with EN54, Part 11
Backward compatibility
Enhanced aesthetics
EManual call point Weather Proof (W5A-RP05SG-K013-01)
View Details
Buy Now
IP rating: IP67
Glass element
SINGLE INPUT MONITOR MODULE (HM-DMMI)
View Details
Buy Now
The common mechanical platform for modules’ enclosure
Low standby current
FACP reads module power voltage
High Power Loop 48V ready
Built-in short circuit isolators
Addressability through rotary switches
Tri-colour Light Pipe
Improved Light Pipe visibility on two sides
Plug-in field wiring terminals
Integrated DIN rail brackets
Lasered engraved label data
IP rate 30
Intertek Approved
OUTPUT CONTROL MODULE (HM-DCMO)
View Details
Buy Now
Common mechanical platform for modules’ enclosure
Low standby current
FACP reads module power voltage
High Power Loop 48V ready
Built-in short circuit isolators
Addressability through rotary switches
Tri-colour Light Pipe
Improved Light Pipe visibility on two sides
Plug-in field wiring terminals
Integrated DIN rail brackets
Lasered engraved label data
IP rate 30
Intertek Approved
LOOP ISOLATION MODULE (HM-DISO)
View Details
Buy Now
Short-circuit isolation
DIN rail mounting Option
Tri-color LED status
Plug-in connectors
Specifications: EN54-17
LPCB approved
DXC NETWORK CARD (795-099)
View Details
Buy Now
Manufactirer : Morley IAS by Honeywell
Part Number : 795-099
Network Communication Card Kit For Morley DXc Fire Alarm Panel Range
One Network Card Required Per Panel
Designed For Use With The Morley DXc1, DXc2 and DXc4 Panels
WSO-PR-NO5/WSS-PR-N05 (Sounder/ Sounder Flasher)
View Details
Buy Now
Large cable access
EN54-3 Approved
Rear or surface cable entry
Loop continuity spring
Common base with detectors (B501AP) Morley IAS Protocol
32 tone selection to cover many markets
Address tag for clear indication
Anti-tamper feature
In-built isolation options
Simple familiar rotary wheel address controls
Monitoring Control Panel (BY-350-DC36U)
View Details
Buy Now
Input Voltage:AC100-120V/ 200-240V
Output voltage:DC36V
IP Level:IP20
Operation Temp:0-40℃
Output current:Max 8A
Output power:Maximum 288W
Communication distance:Up to 1000 meters
Carrying Capacity:Maximum 255 devices
No.of Lines:2 lines
Certificate: UL
Emergency Lighs for Monitoring System (BY-Z2745U)
View Details
Buy Now
Mounting Method:Surface/Recessed
Input Voltage :DC36V
Light Source:SMD2835x27pcs
CRI>80
Lumen Output :300lm
IP Level :IP65
Operation Model:Maintained/Non-Maintained
Battery:LiFepo4 3.2V 3600mAh
Battery Charge Time :24H
Emergency Time :3H
Recessed Kit(Optional)
Certificate:UL
Exit Sign for Monitoring System (BY-B2308U)
View Details
Buy Now
Input Voltage :DC36V
CRI>80
Mounting Method : Ceiling/Wall/Recessed/Suspend/End mount
Battery Charge Time :24H
Emergency Time :3H
Operation Model: Maintained
Battery :LiFePo4 3.2V 3000mAh
Viewing distance:30M
IP Level :IP20
Certificate: UL
Emergency Down Light (BY-Z1805U)
View Details
Buy Now
Input Voltage :DC36V
Mounting Method :Recessed
Light Source :SMD 3535 x 1pc
CRI>70
Lumen Output :300lm
Battery Charge Time :24H
Emergency Time :3H
Operation Model:Non-Maintained
Battery :LiFePo4 3.2V 3600mAh
IP Level :IP20
Certificate: UL
Emergency Square Down Light (BY-Z2805U)
View Details
Buy Now
Input Voltage :DC36V
Mounting Method :Surface
Light Source :SMD 3535x1pc
CRI >70
Lumen Output :300lm
Battery Charge Time :24H
Emergency Time :3H
Operation Model :Non-Maintained
Battery :LiFePo4 3.2V 3600mAh
IP Level :IP20
Certificate: UL
Emergency Lightings for Non-Monitoring System (BY-Z2145U)
View Details
Buy Now
Mounting Method:Surface/Recessed
Input Voltage :DC36V
Light Source:SMD2835x27pcs
CRI>80
Lumen Output :300lm
IP Level :IP65
Operation Model:Maintained/Non-Maintained
Battery:LiFepo4 3.2V 3600mAh
Battery Charge Time :24H
Emergency Time :3H
Recessed Kit(Optional)
Certificate:UL
Exit Sign for Non-Monitoring System (BY-B2108E)
View Details
Buy Now
Input Voltage :DC36V
CRI>80
Mounting Method : Ceiling/Wall/Recessed/Suspend/End mount
Battery Charge Time :24H
Emergency Time :3H
Operation Model: Maintained
Battery :LiFePo4 3.2V 3000mAh
Viewing distance:30M
IP Level :IP20
Certificate: UL
Emergency Down Light (BY-Z1003S / BY-Z1005S)
View Details
Buy Now
Input Voltage :DC36V
Mounting Method :Recessed
Light Source :SMD 3535 x 1pc
CRI>70
Lumen Output :300lm
Battery Charge Time :24H
Emergency Time :3H
Operation Model:Non-Maintained
Battery :LiFePo4 3.2V 3600mAh
IP Level :IP20
Certificate: UL